    YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance

    Ask Lasest Price
    Brand Name : YBX
    Model Number : YB11A4-3A-Q(R)
    Certification : cUL, TUV, CQC, CE, ROHS
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 500000 Piece/Pieces per Month
    Delivery Time : 15-25 days
    • Product Details
    • Company Profile

    YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance

    YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance


    IEC Inlet Filter With Socket


    EMI Filter Specification:


    ItemEmi Power Filter
    ModelEmi Power Filter YB-A
    Transfer FunctionLow Pass
    Package TypeSurface Mount
    Nominal Center Frequency10K-30MHZ
    Insertion Loss60~90dB
    Input Impedance50Ω
    Rated Voltage125VAC 250VAC
    Rated Current1A 3A 6A 10A
    Environmental Temperature40°C
    Temperature Range25 / 085 / 21
    Operating Frequency50/60HZ
    Line to Line1450VDC
    Line to Ground2250VDC
    Maximum Leakage Current115VAC/50HZ 0.3uA Max
    MOQ500pcs
    PriceUSD1~2/Meter
    Lead Time5~15 weekday

    Features:


    1. Excellent performance/compact structure


    2. Optional medical versions((R5) type)


    3. Quick connect(6.35*0.8mm),solder or wire


    4. High performance and high attenuation power filters with IEC 320 socket


    5. (R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current and high hipot testing.


    6. There are a variety of parts and combinations to meet different customer's EMC tests.


    Typical Applications:


    -- Specially designed for LCD and PDP TV,medical applications,general electrical appliances.


    -- Medical equipment


    -- Test and measurement equipment


    -- Small and medium-sized machines and household equipment


    Rule of Nomination of IEC Inlet Fiter


    YB11A4-10A-Q
    |||||
    Single PhaseCircuitDimensionCurrentOutput Connection
    11:11 circuitA46A : 6 ampQ:fast-on tab 250
    8A : 8 ampW:wire
    10A :10 ampS:Solder Lug Terminals

    *Q: Fast-on 6.35x0.8mm S: solder 4.0x0.8mm W: UL1015 18awg


    Filter Selection Table:


    Part No.CaseRated Currents (A)Output Connections
    YB11A4A41Fast-on terminal
    YB11A4A43
    YB11A4A46Wire
    YB11A4A48
    YB11A4A410Solder Lug Terminals

    Tabulates:


    Model No.Rated Current
    @40°C
    Terminal Options*

    Bleeder resistor

    (optional)


    G
    Leakage current 250V/50HzElectrical SchematicRated Voltage(V)Operating Frequency(Hz)
    YB11A3-1A1AQSW--

    <0.8mA

    Fig.1

    115/250V


    50/60Hz

    YB11A3-2A2AQSW--Fig.1
    YB11A3-3A3AQSW--Fig.1
    YB11A3-4A4AQSW--Fig.1
    YB11A3-6A6AQSW--Fig.1
    YB11A3-8A8AQSW--Fig.1
    YB11A3-10A10AQSW--Fig.1
    YB11A3-15A15AQSW--Fig.1
    YB11A4-1A1AQSW--Fig.1
    YB11A4-2A2AQSW--Fig.1
    YB11A4-3A3AQSW--Fig.1
    YB11A4-4A4AQSW--Fig.1
    YB11A4-6A6AQSW--Fig.1
    YB11A4-8A8AQSW--Fig.1
    YB11A4-10A10AQSW--Fig.1
    YB11A4-15A15AQSW--Fig.1

    Medical Type Tabulates:


    Model No.Rated Current
    @40°C
    Terminal OptionsBleeder resistor](optional)Medical equipment
    5

    G
    Leakage current 250V/50HzElectrical Schematic
    Rated Voltage(V)Operating Frequency(Hz)

    YB11A3-1A-x(R5)1AQSW15-

    <5μA

    Fig.2

    115/250V

    50/60Hz

    YB11A3-2A-x(R5)2AQSW15-Fig.2
    YB11A3-3A-x(R5)3AQSW15-Fig.2
    YB11A3-4A-x(R5)4AQSW15-Fig.2
    YB11A3-6A-x(R5)6AQSW15-Fig.2
    YB11A3-8A-x(R5)8AQSW15-Fig.2
    YB11A3-10A-x(R5)10AQSW15-Fig.2
    YB11A3-15A-X(R5)15AQSW15-Fig.2
    YB11A4-1A-x(R5)1AQSW15-Fig.2
    YB11A4-2A-x(R5)2AQSW15-Fig.2
    YB11A4-3A-x(R5)3AQSW15-Fig.2
    YB11A4-4A-x(R5)4AQSW15-Fig.2
    YB11A4-6A-x(R5)6AQSW15-Fig.2
    YB11A4-8A-x(R5)8AQSW15-Fig.2
    YB11A4-10A-x(R5)10AQSW15-Fig.2
    YB11A4-15A-X(R5)15AQSW15-

    Fig.2


    Electrical Schematic:



    Mechanical Dimension(Unit: mm)



    CaseABCDEFGHIJK
    A35628.521312412.711.813.53.26.3*0.8
    A45628.521312412.711.813.53.26.3*0.8
    Tolerances±1±1±1±1±0.15±1±0.5±0.5±0.5±1±0.15

    Insertion loss table(In 50ohm system according IEC/CISPR No.17)


    YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance


    Measuring Equipment


    Before production begins, we test the raw materials in our laboratory to ensure they meet our quality standards, environmental friendliness and safety. Salt spray tester, constant temperature and humidity tester, and pressure tester are some of the testing equipment we use to ensure the quality of our EMI filters from the source.


    YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance

    Quality YB11A4-10A-Q 110V/250V Plug In EMI Filter IEC Inlet Filter For Medical Appliance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Yanbixin Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)